AC To AC Solid State Relay
Salient Features
Advantages
Precaution
Application
Input Specification & Output Specification Technical Data
INPUT SPECIFICATION | OUTPUT SPECIFICATION | |||||||||
INPUT ON VAC | INPUT OFF VAC | INPUT CURR mA | VDRM VPK | IT A | VTM VAC | ITSM A | IDRM mA | IHO mA | DV/DT V | I2t A2S |
180 - 280 | 1.0 | 6 - 12 | 200-800 | 10 | 1.6 | 100 | 10 | 75 | 200 | 50 |
- | 16 | 1.6 | 160 | 10 | 75 | 200 | 120 | |||
- | 25 | 1.85 | 260 | 10 | 150 | 250 | 300 | |||
- | 40 | 1.85 | 300 | 10 | 150 | 250 | 400 | |||
400-800 | 25 | 1.6 | 400 | 12 | 120 | 500 | 1250 | |||
- | 40 | 1.6 | 500 | - | 120 | 500 | 1250 | |||
- | 50 | 1.9 | - | - | 250 | 1000 | 1250 |
TYPE OF S S R | OUTPUT SPECIFICATION | LOAD CURRENT @ 55o C. WITH HEAT SINK | INPUT ON VDC | INPUT OFF VDC | INPUT CURRENT mA | ||
LOAD VOLTAGE | CURRENT AMP AT 20o C | I2t A2S | |||||
EMT 48 10 AC | 480VAC PIV 800VPK 1200VPK | 10 | 50 | 6AMP | 180 - 280 VAC | 1.0 | 1-20 |
EMT 48 16 AC | 16 | 120 | 10 AMP | ||||
EMT 48 25 AC | 25 | 300 | 16 AMP | ||||
EMT 48 40 AC | 40 | 450 | 24 AMP | ||||
EMT 48 50 AC | 50 | 3000 | 32 AMP | ||||
EMT 48 75 AC | 75 | 5100 | 45 AMP | ||||
EMT 48 100 AC | 100 | 7200 | 52 AMP | ||||
EMT 48 125 AC | 125 | 8200 | 66 AMP | ||||
EMT 48 150 AC | 150 | 18000 | 82 AMP | ||||
EMT 48 200 AC | 200 | 25000 | 106 AMP | ||||
EMT 48 250 AC | 250 | 32000 | 132 AMP | ||||
EMT 48 300 AC | 300 | 45000 | 160 AMP |
|
|
|
EMTECH SOLUTION
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |